Outdoor Resin Cast Wound Current Transformers

Engineered for durability and precision, these transformers are designed to perform in outdoor medium-voltage environments, ensuring safe and accurate current measurement under the toughest conditions.

Outdoor Resin Cast Wound Current Transformers

Engineered for durability and precision, these transformers are designed to perform in outdoor medium-voltage environments, ensuring safe and accurate current measurement under the toughest conditions.

Overview

The Outdoor Resin Cast Wound Current Transformers provide superior insulation, weather resistance, and reliability. With a wide primary current range and high short-time current withstand capability, they are built to handle the demands of utility and industrial applications while maintaining long-term accuracy and operational safety.

Key Features

Resin Cast Construction
Delivers robust insulation and protection against environmental factors.
Wide Primary Current Range
Supports 15 A to 1600 A, accommodating diverse system requirements.
High Current Withstand:
Capable of handling short-time currents up to 700 × Ip or 50 kA, ensuring operational safety during faults.
Versatile Panel Fit
Offers multiple core options (up to 3) and secondary terminals (up to 8) for flexible installation.

Applications

Technical Specifications

Type Particulars 17.5kV 24 kV 36 kV
Current Transformer Rated Primary Current (Ip)
Rated Secondary Current (Is) 1 or 5 1 or 5 1 or 5 1 or 5 1 or 5
Rated Short Time Current (Ith)  Max. 50 kA (1000 x In) Max. 50 kA (1000 x In)  Max. 50 kA (1000 x In) Max. 50 kA (1000 x In) Max. 50 kA (1000 x In)
Max. Possible Cores 3 3 3 3 3
Max. Secondary Terminals 12 12 12 12 12
Potential Transformer Rated Primary Voltage 3300/√3 V 6600/√3 V 11000/√3 V 22000/√3 V 33000/√3 V
Rated Secondary Voltage 100/√3 or 110/√3 or 120/√3 100/√3 or 110/√3 or 120/√3 100/√3 or 110/√3 or 120/√3 100/√3 or 110/√3 or 120/√3 100/√3 or 110/√3 or 120/√3
Maximum Rated Voltage Factor 1.2 Continuous & 1.9 for 8 hrs 1.2 Continuous & 1.9 for 8 hrs 1.2 Continuous & 1.9 for 8 hrs 1.2 Continuous & 1.9 for 8 hrs 1.2 Continuous & 1.9 for 8 hrs
Max. Secondary Terminals 3 3 3 3 3
Common Parameters Basic Insulation Level (BIL) 3.6/10/40 kV 7.2/20/60 kV 12/28/75 kV 24/50/125 kV 36/70/170 kV
Rated Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz

Compliance & Certification

  • IEC 61869
  • ISO 9001:2015 Quality Management System
  • RoHS Compliant

Reliable measurement. Safe design. Trusted performance.

Request a Quote
Outdoor Resin Cast Wound Current Transformers
Download Datasheet